Sign In | Join Free | My himfr.com
Home > PLC Industrial Automation >

Twin Timer Omron PLC H3CRF8 100 - 240V AC For Automation Equipment

Changsha Zhinian Automation Equipment Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Twin Timer Omron PLC H3CRF8 100 - 240V AC For Automation Equipment from wholesalers
     
    Buy cheap Twin Timer Omron PLC H3CRF8 100 - 240V AC For Automation Equipment from wholesalers
    • Buy cheap Twin Timer Omron PLC H3CRF8 100 - 240V AC For Automation Equipment from wholesalers
    • Buy cheap Twin Timer Omron PLC H3CRF8 100 - 240V AC For Automation Equipment from wholesalers

    Twin Timer Omron PLC H3CRF8 100 - 240V AC For Automation Equipment

    Ask Lasest Price
    Brand Name : Omron
    Model Number : H3CR-F8
    Supply Ability : 10pc/per week
    Price : $19.00 - $139.00/Pieces
    Payment Terms : T/T, western union
    MOQ : 1 Piece
    • Product Details
    • Company Profile

    Twin Timer Omron PLC H3CRF8 100 - 240V AC For Automation Equipment

    OMRON PLC Twin Timer H3CR-F8 100-240V AC NEW IN BOX 6 month warranty

    H3CR-F Features:

    • Wide power supply ranges of High Voltage 100 to 240 VAC/100 to 125 VDC and Low Voltage 24 to 48 VAC/12 to 48 VDC.

    • ON- and OFF-times can be set independently and so combinations of long ON- or OFF-time and short OFF- or ONtime settings are possible.

    • Twenty-four time ranges from 0.05 s to 300 h depending on the model to be used.

    • Models with a flicker ON start or flicker OFF start are available.

    • Easy sequence checks through instantaneous outputs for a zero set value at any time range.

    • Length, when panel-mounted with a Socket, of 80 mm or less.

    • 11-pin and 8-pin models are available.


    100 to 240 VAC 50/60 Hz, 100 to 125 VDC, Output Time-limit: DPDT, Flicker OFF start, Time range: 0.05 to 1.2 s (18 range), 8-pin


    Rated power supply voltage100 to 240 VAC 50/60 Hz
    100 to 125 VDC Ripple 20% max. (If power supply incorporates a single-phase full-wave rectifier)
    Allowable voltage variable range85 to 110% of the power supply voltage
    Power consumptionApprox. 10 VA (at 240 VAC)
    Approx. 2.1 W (at 240 VAC)
    Reset voltage10% max. of rated supply voltage
    Number of time ranges18
    Operation modeFlicker OFF start
    Control output (Type)Time-limit: DPDT
    Control output (Contact output)Resistive load: 250 VAC 5 A (cosφ=1)/5 A at 30 VDC
    Minimum applicable load: 10 mA at 5 VDC (failure level: P Reference value)
    Operating resettingTime-limit operation/Time-limit reset or Self-reset
    Ambient temperature rangeOperating: -10 to 55 ℃ (with no icing)
    Storage: -25 to 65 ℃ (with no icing)
    Ambient humidity rangeOperating: 35 to 85%
    Accuracy of operating time±0.2% FS max.
    ±0.2% ±10 ms in a range of 1.2 s and 3 s
    Setting error±5% FS ±50 ms max.
    Reset time0.1 s max.
    Influence of voltage±0.2% FS max.
    ±0.2% ±10 ms in a range of 1.2 s and 3 s
    Influence of temperature±1% FS max. (±1% ±10 ms in a range of 1.2 s and 3 s)
    Insulation resistance100 MΩ min. (at 500 VDC)
    Dielectric strengthBetween current carrying metal parts and non-current carrying metal parts: 2,000 VAC 50/60 Hz 1 min
    Between control output terminals and operating circuit: 2,000 VAC 50/60 Hz 1 min
    Between contacts of different polarity: 2,000 VAC 50/60 Hz 1 min
    Between non-continuous contacts: 1,000 VAC 50/60 Hz 1 min
    Impulse withstand voltageBetween power terminals: 5 kV
    Between current carrying terminals and exposed non-current carrying metal parts: 5 kV
    Noise immunity±1.5 kV (between power terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
    Static immunityMulfunction: 8 kV, Destruction: 15 kV
    Vibration resistanceDestruction: 10 to 55 Hz, 0.75 mm single amplitude each in 3 directions for 2 h
    Malfunction: 10 to 55 Hz, 0.5 mm single amplitude each in 3 directions for 10 min
    Shock resistanceDestruction: 980 m/s2, 3 times each in 6 directions
    Malfunction: 98 m/s2, 3 times each in 6 directions
    Life expectancy (relay output)Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1800 operations/h)
    Mechanical: 20 million operations min. (under no load at 1,800 operations/h)
    Degree of protectionIP40 (panel surface)
    Connecting method8-pin round socket
    WeightApprox. 100 g


    Quality Twin Timer Omron PLC H3CRF8 100 - 240V AC For Automation Equipment for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Changsha Zhinian Automation Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)