Sign In | Join Free | My himfr.com
Home > Omron PLC CJ1W >

Flag Synchronization Omron PLC CJ1W-CLK23 Programmable Controller

Changsha Zhinian Automation Equipment Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now
    Buy cheap Flag Synchronization Omron PLC CJ1W-CLK23 Programmable Controller from wholesalers
     
    Buy cheap Flag Synchronization Omron PLC CJ1W-CLK23 Programmable Controller from wholesalers
    • Buy cheap Flag Synchronization Omron PLC CJ1W-CLK23 Programmable Controller from wholesalers
    • Buy cheap Flag Synchronization Omron PLC CJ1W-CLK23 Programmable Controller from wholesalers
    • Buy cheap Flag Synchronization Omron PLC CJ1W-CLK23 Programmable Controller from wholesalers

    Flag Synchronization Omron PLC CJ1W-CLK23 Programmable Controller

    Ask Lasest Price
    Brand Name : Omron
    Model Number : CJ1W-CLK23
    Supply Ability : 10pc/per week
    Price : $50-500
    Payment Terms : T/T, western union
    • Product Details
    • Company Profile

    Flag Synchronization Omron PLC CJ1W-CLK23 Programmable Controller

    New PLC CJ1W CJ1W-CLK23 Omron Controller With One Year Warranty

    Features

    • Large-capacity data links are easily achieved without programming simply by setting data link tables.

    • Up to 20,000 *1 send/receive words can be set per node for Units (up to 62,000 words for Boards).

    • Data links can be performed with up to 4,000 *2 words per node while ensuring data concurrency.

    • User-set data link tables can be changed while data links are operating. *3

    • Errors for the entire system can be monitored by using error diagnosis support software and a variety of status flags.

    *1. Supported for unit version 1.2 or later.
    *2. CJ1W-CLK23 and 3G8F7-CLK[]3 are supported.
    *3. Supported for CJ1W-CLK23, 3G8F7-CLK[]3, and models ending with "-V1".

    Flag Synchronization Omron PLC CJ1W-CLK23 Programmable Controller


    Specification

    ItemsSpecifications
    ModelCJ1W-CLK23
    3G8F7-CLK23-E
    CJ1W-CLK21-V1 *1
    3G8F7-CLK21-EV1 *1
    TypeWired (shielded twisted-pair cable)
    Communications methodN:N token-bus method
    CodeManchester code
    ModulationBaseband code
    SynchronizationFlag synchronization (conforms to HDLC frames)
    Transmission path formatMultidrop method (bus type)
    Transmission speedThe following are the maximum transmission distances depending on the transmission speed.
    2 Mbits/s: 500 m
    1 Mbits/s: 800 m
    500 kbits/s: 1 km
    Maximum transmission
    distance
    Maximum distance between
    nodes
    Not specified. (Maximum transmission distance must be satisfied for the entire system.)
    MediumSpecified shielded twist-pair cable
    Two signal wires, one shield
    Node connection methodPLC: Connection to terminal block
    Computer: Connection using special (supplied) connector
    Maximum number of nodes32 or 62 nodes *2 *3
    Applicable Programming
    Devices
    CX-Integrator in CX-One, CX-Net in CX-Programmer *3, and Programming Console
    Communications functionsData links and message service
    Number of data link wordsSend words per node: 4,000 words max. (CJ1W-CLK[]3), 1,000 words max. (All other Units)
    Number of send/receive words per node:
    12,000 words max. (Pre-Ver. 1.2)
    20,000 words max. (unit Ver. 1.2 or later)
    Total number of send words per network: 62,000 words max.
    Data link areasPLC: Bit areas (CIO Area, Work Area, Link Area *4), Data Memory (DM), Extended DM Area (EM) Computer:
    FinsGateway event memory
    Message length2,012 bytes max. (including the header)
    RAS functionsPolling node backup function
    Self-diagnosis function (hardware checking at startup)
    Echoback test and broadcast test (using the FINS command)
    Watchdog timer
    Error log function
    Error controlManchester code check
    CRC check (CCITT X16 +X12 +X5 +1)

    *1. Discontinuation models in July 2012.
    *2. With wired models, the maximum number of nodes is 32 if Repeater Units are not used. A Repeater Unit is required
    when building a network with more than 32 nodes. If a Repeater Unit is used, be sure to use only the following
    Controller Link Units or Boards and set the Wired Network 62 Node Enable Bit in the DM Parameter Area software
    switches at all nodes.
    CS1W-CLK23/CLK21-V1
    CJ1W-CLK23/CLK21-V1
    3G8F7-CLK23-E/CLK21-EV1
    *3. CX-Net in CX-Programmer version 3.1 or earlier can be used only in a system with a maximum of 32 nodes (node
    address 1 to 32). If a system is to be used with a maximum of 62 nodes (node addresses 1 to 62), use CX-Net in
    CX-Programmer version 3.2 or higher or the CX-Integrator.
    *4. CJ-series PLCs do not have a Link Area, but LR000 to LR199 are automatically converted CIO 1000 to CIO 1199

    Controller Link Units

    ItemSpecifications
    ModelCJ1W-CLK23
    CJ1W-CLK21-V1 *
    Applicable PLCAll CJ-series CPU Units
    Number of mountable Units8 max.
    Installation siteInstall onto a CPU Backplane or Expansion Backplane (classified as a CPU Bus Unit).
    Storage location of network parameters and
    manually set data link tables
    System Bus Unit Area (in the CPU Unit parameter area).
    Storage location of routing tablesCPU Unit parameter area
    Weight110 g
    Current consumption: 5 V in PLC0.35 A
    Related Products

    Flag Synchronization Omron PLC CJ1W-CLK23 Programmable Controller



    Quality Flag Synchronization Omron PLC CJ1W-CLK23 Programmable Controller for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Changsha Zhinian Automation Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)